EEG

24-channel EXG Recording System

All-in-One eWave24 system

eWave system (QEEG/Brain Mapping) The eWave-24 is a strong and multi-module system for measuring and monitoring up to 24 EXG channels of ECG, EMG, EEG, and EOG signals simultaneously.

Using eWave, you can interpret the information obtained from the qEEG and use it as a clinical tool to evaluate brain function and to monitor changes in brain function due to various interventions such as Neurofeedback or medication.

neurofeedback
QEEG

The Powerful EEG, QEEG, ERP Recording System Optimized the Best Way for EEG

  • Fully integrated into eLife software environment for visualization and real-time analysis.
  • 24 DC-coupled wide-range input channels able to record any type of biological signals (EEG, EMG, ECG, EOG, and connected various sensors)
  • An efficient ERP acquisition system
  • Supports EcOG grids for cortical recording
  • 24-bit resolution with simultaneous sampling of all channels
  • Easy configuration and setup with Smart Box BCI system
  • Rechargeable internal lithium battery
  • Easy configuration and setup with eBridge Simulink environment
  • Simultaneous TMS possible
  • High-Frequency Oscillations (HFOs) recording possible
  • Slow Cortical Potentials (SCPs) recording possible
  • Simultaneous tDCS possible

Techniques

Neurofeedback

Biofeedback

EEG Hospital

QEEG

Clinical-Q

Loreta Neurofeedback

BMI

ERP

Specification

DATA ACQUISITION
ANALOG TO DIGITAL CONVERTER
BIO AMPLIFIER
OTHER SPECIFICATIONS

 

  • Technology: ARM Cortex 32 Processor
  • Processor: 160 MHz
  • Data Connection: Bluetooth wireless, 1 Mb/s, up to 10 meters
  • Number of channels: 8/24/32
  • ADC resolution: 24 bit
  • Linearity error: 7.6 ppm (maximum)
  • Sample rate: 500-1000 samples per second per channel (up to 16000 per channel)
  • Number of channels : 24
  • Amplifier type : Differential; DC
  • Linearity error : 7.6 ppm (maximum)
  • Gain : 4
  • High cut filter : 500 Hz
  • Low cut filter : DC
  • Input voltage range : 2.5 V
  • Maximum analog input voltage : 2.5 V
  • Input impedance : 1000 Giga ohm
  • Input leakage current : 60 pA (typical)
  • Input capacitance : 8 pf
  • Common mode rejection ratio75 dB @ 500 Hz
  • 24 AUX channels: Skin conductance, Temperature, BVP/HR
  • 24 EXG Channels : EMG, EEG, EOG, ECG (8 channels)
  • Power: Battery (Lithium, 3.7 V), Battery Charger 5 V
  • Battery Life: 15 hours on a full charge
Routine EEG
Hospital EEG

This device can be used for routine EEG, Event-Related Potential (ERP) data acquisition for medical and research institutions.The flexible and easy-to-use software enables you to use lots of montages, including Laplacian, Bipolar, Banana, Longitudinal, Double Banana, and QEEG, for EEG recording. The Routine EEG package is coming with the eStim, which is a powerful photic stimulator and enables you to detect abnormal epileptogenic sensitivity to flickering light.

QEEG (Brain Mapping)/EEG

Using eWave, you can interpret the information obtained from the qEEG and use it as a clinical tool to evaluate brain function and to monitor changes in brain function due to various interventions such as Neurofeedback or medication.
The eWave system offers deep insights into brain function by measuring and analyzing EEG activity at 19 locations. The eWave device is integrated with the NeuroGuide software.

The eWave-24 is a strong and multi-module system for measuring and monitoring up to 24 EXG channels of ECG, EMG, EEG, and EOG signals simultaneously.
It enjoys innovative high precision and low noise amplifiers as well as the 24-bit ADC, which provides reliable high-quality signals by 1000 samples per second.
The eWave-24 also offers up to 24 AUX channels for peripheral bio-signals such as skin temperature, GSR, respiration, and BVP/HRV. It also has extra digital inputs for triggers to ERP research applications.
Using eWave, you can interpret the information obtained from the qEEG and use it as a clinical tool to evaluate brain function and monitor changes in brain function due to various interventions such as Neurofeedback or medication.
The eWave system offers deep insights into brain function by measuring and analyzing EEG activity.

eLife software for EEG/QEEG

  • User-friendly environment
  • Various montages can be added
  • Compatible with different Operating Systems (OS)
  • Great software for visualization and analysis
  • Removing Powerline interference (50 Hz)
  • Designing High-pass and Low-pass filters
  • Analysis of various bio-signals
  • Printing data is possible
  • FFT visualization of recorded signals

Hospital EEG

  • In the “Hospital-EEG” protocol, click on the “Pre-record” tab – before initiating a recording in the impedance section. Make sure that all channels are connected correctly. To apply gel into the cap, run the software and click on the arrow indicated in the image.
  •  The amount of impedance in each electrode will be displayed below each item in ohm unit.
Hospital EEG

Loreta Neurofeedback

LoRETA neurofeedback is a type of neurofeedback that uses a 3D image of the brain activity to guide the training. Neurofeedback is a process of teaching the brain to regulate itself better by using feedback from sensors attached to the scalp. LoRETA neurofeedback can target specific brain regions and networks that are involved in various cognitive, emotional, and behavioral functions. LoRETA neurofeedback can help with various conditions such as concussion, anxiety, depression, ADHD, eating disorders, chronic pain, insomnia, and more. LoRETA neurofeedback is also used for enhancing mental performance and well-being. LoRETA neurofeedback is based on scientific research and is approved by the FDA.

QEEG / Brain Mapping

  • Demanded montages must be chosen for optimal display in a Routine
    EEG recording.
  • You can also design new montages in the software.
  • To select the montage, right-click on the scope screen and select the preferred option from the “Montage” menu. Select the “QEEG” option to record QEEG
×

Hello!